? Ceramic Capacitive Pressure Transducer - Jiucheng is a Manufacturer

      <wbr id="o7fmd"><pre id="o7fmd"></pre></wbr>
      <form id="o7fmd"><pre id="o7fmd"></pre></form>
      • Ceramic Capacitive Pressure Transducer

      TYPE:UCS2

      NAME:UCS2 Ceramic Capacitive Pressure Transducer

      The pressure sensor element Ceracore UCS2 delivers a pressure-proportional voltage signal . We offer support for the integration of the Ceracore UCS2 into the customized application.

      UCS2 Ceramic Capacitive Pressure Transducer

      UCS2 Ceramic Capacitive Pressure Transducer Application:

      The pressure sensor element Ceracore UCS2 delivers a pressure-proportional voltage signal . We offer support for the integration of the Ceracore UCS2 into the customized application.

      UCS2 Ceramic Capacitive Pressure Transducer Benefits:

      – Dry capacitive ceramic sensor
      – Basic ceramic material (99.9 % Al?2O3?)
      – Extremely high overload limit
      – Absolutely resistant to wear
      – High temperature stability
      – High long-term stability
      – no hysteresis
      – Corrosion-resistant
      – Active electronics
      – Sensor-specific signal conditioning
      – High-accuracy pressure measurement with temperature stability?Measuring principle

      UCS2 Ceramic Capacitive Pressure Transducer Measuring Principle:

      The UCS2?Ceramic Capacitive Pressure Transducer?basic material is Al2O3(99.9 %), a highly resistant ceramic material for many aggressive gases and liquids. Cylindrical ceramic components (diaphragm, meter body) are bonded to form a high- strength, hermetically sealed pressure sensor element. With absolute pressure sensors, the vacuum of 3.0 x 10-6 mbar created in the production process between the diaphragm and the meter body remains permanently. This permits pressure measurements related to the vacuum. With gauge pressure sensors, the back of the diaphragm is vented, i.e. this sensor measures the gauge pressure relative to the atmospheric pressure. Elec- trically, the sensor element represents a plate capacitor whose capacitance change is the dimension for the pressure change. The capacitive measuring process satisfies the highest requirements concerning resolution and reproducibility. Together with the hysteresis-free behavior of the material Al2O3, it is the basis for the excellent specifications of the sensor. In addition, the Ceracore UCS2 is a dry measuring cell, i.e. there is no separating diaphragm or filling fluid which could influence the measurement. A further advantage of the capacitive ceramic sensor is its high overload resistance. After removal of the overload, it returns to the initial position without any damage or hysteresis.

      Input
      Measured variable:Choice of gauge pressure or absolute pressure
      Measuring range:Gauge pressure measurement 0.1 to 70 bar, absolute pressure measurement 0.2 to 70 bar

      Output
      Zero point :0.50 V ± 0.05 V; applies to the respective lower range-value of the measuring range
      Span:4.00 V ± 0.05 V
      Characteristic curve:linear; max. non-linearity ≤0.2 % of span
      Load:≥10 kΩ or ≤300 pF (with signal deviation <0.1 % of span)
      Rise time:approx. 1 ms
      Switch-on time:max. 10 ms
      Long-term stability:max. 0.1 % of span per year
      Output signal:0.5 to 4.5 V

      Power supply
      Supply voltage:
      ? 5 V DC stabilized, minimum 4.5 V / maximum 5.5 V
      ? Influence of supply voltage: no influence on linearity / proportional on lower range-value/ proportional on span, no influence on temperature compensation
      Current consumption :Maximum 2 mA at a supply voltage of 5 V

      Power supply
      Supply voltage 5 V DC stabilized, minimum 4.5 V / maximum 5.5 VInfluence of supply voltage: no influence on linearity / proportional on lower range-value?/ proportional on span, no influence on temperature compensation
      Current consumption Maximum 2 mA at a supply voltage of 5 V
      Operating conditions: Installation
      Orientation Arbitrary. Operate the sensor system with the diaphragm pointing downwards. Otherwise?observe the position dependent zero point shift for small pressure ranges (≤ 400 mbar).
      Weight approx. 17 to 23 g, depending on measuring range
      Operating conditions: Environment
      Ambient temperature range ?-40 °C to +125 °C (also applies to storage temperature)
      Degree of protection IP 00 as per DIN 60529 (IEC529); Climate class 3K3 DIN EN 60721-3-3
      Operating conditions: Process
      Reference?operating?conditions As?per?DIN?IEC?60770,?T?=?25?°C
      Media Gases?and?liquids
      Material Diaphragm:?aluminum?oxide?ceramic?Al2O3?(99.9?%)
      Process?temperature?limits -40?°C?to?+125?°C,?compensation?temperature?-20?°C?to?+80?°C
      Thermal change Thermal change of the lower range-value in the compensation temperature range: max. ±0.75 % of span, with extended specification ±1 % of span
      Thermal change of output span in the compensation temperature range: max. ±0.5 % of span. With?Measuring ranges ≤0.4 bar ±0.8 % of span, with extended specification ±1 % of span
      Limiting medium pressure range Overload limit: see “Ordering information” section, Overload influence: negligible
      Vacuum resistance UCS2?with?nominal?value?400?mbar?up?to?70?bar:?0?mbar?abs
      UCS2?with?nominal?value?200?mbar:?500?mbar?abs?(Version?M?in?Ordering?information)
      UCS2?with?nominal?value?100?mbar:?700?mbar?abs?(Version?L?in?Ordering?information)
      Ceracore UCS2 10 Sensor range; Overload (other measuring ranges and special versions on request)
      A 0…100?mbar?/?10?kPa/1.5?psi?absolute;?4?bar/400?kPa/60?psi
      B 0?to?200?mbar?/20?kPa/3?psi?absolute;?6?bar/600?kPa/?90?psi
      C 0?to?400?mbar?/40?kPa/6?psi?absolute;?6?bar/600?kPa/?90?psi
      D 0?to?1?bar?/100?kPa/15?psi?absolute;?10?bar/1?MPa/?150?psi
      E 0?to?2?bar?/200?kPa/30?psi?absolute;?18?bar/1.8?MPa/?270?psi
      F 0?to?4?bar?/400?kPa/60?psi?absolute;?25?bar/2.5?MPa/?375?psi
      G 0?to?10?bar?/1?MPa/150?psi?absolute;?40?bar/4?MPa/?600?psi
      H 0?to?20?bar?/2?MPa/300?psi?absolute;?40?bar/4?MPa/?600?psi
      I 0?to?40?bar?/4?MPa/600?psi?absolute;?60?bar/6?MPa/?900?psi
      J 0?to?70?bar?/7?MPa/1050?psi?absolute;?105?bar/10.5?MPa/?1575?psi
      L 0?to?100?mbar?/10?kPa/1.5?psi?relative;?4?bar/400?kPa/?60?psi
      M 0?to?200?mbar?/20?kPa/3?psi?relative;?6?bar/600?kPa/?90?psi
      N 0?to?400?mbar?/40?kPa/6?psi?relative;?6?bar/600?kPa/?90?psi
      O 0?to?1?bar?/100?kPa/15?psi?relative;?10?bar/1?MPa/?150?psi
      P 0?to?2?bar?/200?kPa/30?psi?relative;?18?bar/1.8?MPa/?270?psi
      R 0?to?4?bar?/400?kPa/60?psi?relative;?25?bar/5?MPa/?375?psi
      S 0?to?10?bar?/1?MPa/150?psi?relative;?40?bar/4?MPa/?600?psi
      T 0?to?20?bar?/2?MPa/300?psi?relative;?40?bar/4?MPa/?600?psi
      U 0?to?40?bar?/4?MPa/600?psi?relative;?60?bar/6?MPa/?900?psi
      V 0?to?70?bar?/7?MPa/1050?psi?relative;?105?bar/10.5?MPa/?1575?psi
      20 Calibration;?Unit
      A see?additional?specification?(special?measuring?ranges?with?extended?specifications)
      1 Sensor?range;?mbar/bar
      2 Sensor?range;?kPa/MPa
      3 Sensor?range;?psi
      UCS2 -A? ?|? ?A ?|? ?1? ? ? A? ? ? ?1? |? ? ?AAA

      The pressure sensor element Ceracore UCS2 delivers a pressure-proportional voltage signal . We offer support for the integration of the Ceracore UCS2 into the customized application.
      More complete HD video from YouTube: click here

      今天晚上开的什么码 乐至县| 扶沟县| 延安市| 张家界市| 盐边县| 涟水县| 济源市| 大丰市| 江津市| 锡林郭勒盟| 肃北| 大悟县| 东辽县| 雷州市| 万载县| 明光市| 新疆| 惠安县| 深圳市| 玉树县| 峡江县| 西宁市| 连云港市| 乐业县| 玉溪市| 杭州市| 桂平市| 乌拉特中旗| 辽宁省| 耒阳市| 南平市| 南江县| 崇州市| 宕昌县| 汝南县| 宜君县| 郸城县| 定陶县| 张家川| 广汉市| 马鞍山市| http://m.f8xpl4.top http://www.k30478.cn http://m.sinay5x4.pw http://baidu.k0ha3k.top http://wap.lsj9uu.club http://qq.rno1o0.top